harga Infant Radiant Warmer GEA HKN 93B

Infant Radiant Warmer GEA HKN 93B

Berat: 45.0 kg SKU: 57200MPM No Registrasi: AKL 20902021890

Dijamin original dan bergaransi

HKN 93B is added with LED phototherapy unit, timer to count phototherapy time

 

Harga Infant Radiant Warmer GEA HKN 93B :

Rp102,850,000.00
Rp82.280.000 20% off
Tersedia cicilan hingga 12 bulan dengan kartu kredit BNI
Quantity:

Deskripsi Infant Radiant Warmer GEA HKN 93B

Type : Infant Radiant Warmer with Oxygen Tank 93B

Features :

- Serve control: Skin-temp, Mattress-temp and Oxygen concentration

- Automatic control or manual control selectable

- Sensor used to measure the bed or skin temperature

- RS232 Connector for contact with computer monitor

- Light touch control panel waterproof.

- Set temperature and actual temperature separately display

- Heating consumption 0~100%

- Four alarm identification

- Radiate box adjustable in two direction from 0o~90o

- Bassinet gradient adjustable in ±15 angel degree

- X-ray tray under bassinet, convenient for taking x-ray photo

- Far-infrared quartz tube as heater

Main Technical Data :

* Power suplly requirements                                                                                                        

- Voltage :  AC 220V ± 10%, 50 Hz ± 10% or 110 V ± 10%, 60 Hz ± 2%

- Power rate :  ≤ 1200 VA

* Operating condition                                                                                                       

- Environment temp : 18oC ~ 30oC

- Relative humidity : < 80%

- Environment air flow speed : < 0,3 m/s

* Temperature control                                                                                                     

- Bed temperature control range : 25’C~37’C

- Skin temperature control range :  34’C~37’C

- Temperature control accuraty : ± 0.1oC

- Measure temp error : ≤ ± 0.3oC

- Mattress temperature uniformity  : ≤ 2.0oC

- Temperature rise time : ≤ 38 minutes

- Far-infrared wavelength :1 um ~ 3 um

- Apgar time : Continuous record time and audible alarm every 1,5,10 minutes

- Radiator horizon angle : 0, 30, 60 degree tow ways adjustable

- Bassinet tilt angel adjustable : ±15 degree

- Mattress tray dimensions : 750 mm x 585 mm 

Specifications :

- Bassinet Max load : 10 kg

- Instrument shelf max load : 2 kg

-I.V. Pole max load : 2 kg

- Height from ground to radiator : 180 cm

- Height from ground to bed : 85 cm

- Packing size : 127 cm x 81 cm x 103 cm main body

- Gross weight :  130 kg

Diskusi Infant Radiant Warmer GEA HKN 93B


Tidak menemukan jawaban yang Anda cari? Tanya disini!
Pertanyaan Anda:

Review Infant Radiant Warmer GEA HKN 93B


Belum ada ulasan.
Perlindungan Pembeli
Full refund jika pesanan tidak diterima
Refund atau tetap miliki produk yang tidak sesuai dengan deskripsi
Rekomendasi Produk
Terakhir Dilihat
Selex ON Strip Cek CK - MB 20T
25% off
Rp2.200.000
Rp1.644.500
Medi ECG 1106L
10% off
Rp34.969.000
Rp31.472.100
Reagen Golongan Darah Anti-B
30% off
Rp121.550
Rp83.925
Mono Drugs Test 3 Parameter 25 Kaset/Box
10% off
Rp1.224.000
Rp1.101.600
Oncoprobe Rapid Test HCG 25 Strip/Box
10% off
Rp432.000
Rp388.800
ECG 6 Channel EDAN SE601C
20% off
Rp29.750.000
Rp23.800.000
Dr Ortho OH 609 CDH Pediatric Hip Splint
16% off
Rp1.214.400
Rp1.012.000